Hitachi ABB Power Grids has an advisory and update available to handle multiple vulnerabilities in its eSOMS Telerik, according to a report with CISA.

The vulnerabilities include path traversal, deserialization of untrusted data, improper input validation, inadequate encryption strength, and insufficiently protected credentials. Successful exploitation of these remotely exploitable vulnerabilities, which Hitachi ABB Power Grids self-reported, could allow an attacker to upload malicious files to the server, discover sensitive information, or execute arbitrary code.

Hitachi ABB Power Grids reports the vulnerabilities affect the following eSOMS products: All versions prior to 6.3 using a version of Telerik software.

In one vulnerability there is a path traversal in RadChart in Telerik UI for ASP.NET AJAX that allows a remote attacker to read and delete an image with extension .BMP, .EXIF, .GIF, .ICON, .JPEG, .PNG, .TIFF, or .WMF on the server through a specially crafted request.

CVE-2019-19790 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.

Schneider Bold

In addition, Progress Telerik UI for ASP.NET AJAX through 2019.3.1023 contains a .NET deserialization vulnerability in the RadAsyncUpload function. This is exploitable when the encryption keys are known.

CVE-2019-18935 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.

Also, Progress Telerik UI for ASP.NET AJAX before R2 2017 SP2 does not properly restrict user input to RadAsyncUpload, which allows remote attackers to perform arbitrary file uploads or execute arbitrary code.

CVE-2017-11357 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.

In another issue, Telerik.Web.UI in Progress Telerik UI for ASP.NET AJAX before R1 2017 and R2 before R2 2017 SP2 uses weak RadAsyncUpload encryption, which allows remote attackers to perform arbitrary file uploads or execute arbitrary code.

CVE-2017-11317 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.

In addition, Telerik.Web.UI.dll in Progress Telerik UI for ASP.NET AJAX before R2 2017 SP1 and Sitefinity before 10.0.6412.0 does not properly protect Telerik.Web.UI.DialogParametersEncryptionKey or the MachineKey, which makes it easier for remote attackers to defeat cryptographic protection mechanisms, leading to a MachineKey leak, arbitrary file uploads or downloads, XSS, or ASP.NET ViewState compromise.

CVE-2017-9248 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.

Also, there is an absolute path traversal vulnerability in the RadAsyncUpload control in the RadControls in Telerik UI for ASP.NET AJAX before Q3 2012 SP2 allows remote attackers to write to arbitrary files, and consequently execute arbitrary code, via a full pathname in the UploadID metadata value.

CVE-2014-2217 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.

In addition, there is a cross-site scripting (XSS) vulnerability in Telerik UI for ASP.NET AJAX RadEditor control 2014.1.403.35, 2009.3.1208.20, and other versions which allows remote attackers to inject arbitrary web script or HTML via CSS expressions in style attributes.

CVE-2014-4958 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 4.3.

The product sees action mainly in the energy sector, and on a global basis.

No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage the vulnerabilities.

Hitachi ABB Power Grids published an advisory for eSOMS Telerik and advises users to update to eSOMS Version 6.3 as soon as possible.

For additional information and support, contact a product provider or Hitachi ABB Power Grids service organization. For contact information, click on Hitachi ABB Power Grids contact-centers.

Recommended security practices and firewall configurations can help protect a process control network from attacks that originate from outside the network. Such practices include ensuring applications and servers are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, are separated from other networks by means of a firewall system that has a minimal number of ports exposed, and others that must be evaluated case by case. Sensitive application servers should not be used for Internet surfing, instant messaging, or receiving e-mails. Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.

Pin It on Pinterest

Share This