Mitsubishi Electric has new software available to handle improper restriction of XML external entity reference and uncontrolled resource consumption vulnerabilities in its Factory Automation Engineering Software Products, according to a report with CISA.
Successful exploitation of these remotely exploitable vulnerabilities, which Mitsubishi Electric PSIRT reported, could allow a local attacker to send files outside of the system as well as cause a denial-of-service condition.
In one issue, the vulnerability could allow a malicious attacker to send a file on the computer running the product to the outside. CVE-2020-5602 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 5.3.
In addition, another vulnerability could allow a malicious attacker to cause the product to enter a denial-of-service condition.
CVE-2020-5603 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
The following versions of Factory Automation engineering software products suffer from the vulnerabilities:
- CPU Module Logging Configuration Tool, Versions 1.94Y and prior
- CW Configurator, Versions 1.010L and prior
- EM Software Development Kit (EM Configurator), Versions 1.010L and prior
- GT Designer3(GOT2000), Versions 1.221F and prior
- GX LogViewer, Versions 1.96A and prior
- GX Works2, Versions 1.586L and prior
- GX Works3, Versions 1.058L and prior
- M_CommDTM-HART, Version 1.00A
- M_CommDTM-IO-Link, Versions 1.02C and prior
- MELFA-Works, Versions 4.3 and prior
- MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool, Versions 1.004E and prior
- MELSOFT FieldDeviceConfigurator, Versions 1.03D and prior
- MELSOFT iQ AppPortal, Versions 1.11M and prior
- MELSOFT Navigator, Versions 2.58L and prior
- MI Configurator, Versions 1.003D and prior
- Motion Control Setting, Versions 1.005F and prior
- MR Configurator2, Versions 1.72A and prior
- MT Works2, Versions 1.156N and prior
- RT ToolBox2, Versions 3.72A and prior
- RT ToolBox3, Versions 1.50C and prior
The products see use in multiple industry sectors, and on a global basis.
No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage the vulnerabilities.
Mitsubishi said affected users should download the latest version of each software product and update it.
- The fixed versions are as follows:
- CPU Module Logging Configuration Tool, Version 1.100E or later
- CW Configurator, Version 1.011M or later
- EM Software Development Kit (EM Configurator), Version 1.015R or later
- GT Designer3(GOT2000), Version 1.225K or later
- GX LogViewer, Version 1.100E or later
- GX Works2, Version 1.590Q or later
- GX Works3, Version 1.060N or later
- M_CommDTM-HART, Version 1.01B or later
- M_CommDTM-IO-Link, Version 1.03D or later
- MELFA-Works, Version 4.4 or later
- MELSEC-L Flexible High-Speed I/O Control Module Configuration Tool, Version 1.005F or later
- MELSOFT FieldDeviceConfigurator, Version 1.04E or later
- MELSOFT iQ AppPortal, Version 1.14Q or later
- MELSOFT Navigator, Version 2.62Q or later
- MI Configurator, Version 1.004E or later
- Motion Control Setting, Version 1.006G or later
- MR Configurator2, Version 1.100E or later
- MT Works2, Version 1.160S or later
- RT ToolBox2, Version 3.73B or later
- RT ToolBox3, Version 1.60N or later
For affected users who cannot immediately update the software products, Mitsubishi recommends the following mitigation measures to minimize the risk of these vulnerabilities:
- Make sure the file is obtained from the correct acquisition route when users receive a project file or a configuration data file from another person via mail, USB memory, file server, etc. (Or, check that there is no file of unknown source.)
- Operate the products under an account that does not have administrative privileges.
- Install an antivirus software in your personal computer using the products.
- Restrict network exposure for all control system devices or systems to the minimum necessary, and ensure that they are not accessible from untrusted networks and hosts.
- Locate control system networks and remote devices behind firewalls and isolate them from the business network.
- Use Virtual Private Network (VPN) when remote access is required.