Rockwell Automation has an update available to handle a protection mechanism failure in its FactoryTalk Services Platform, according to a report with CISA.
Successful exploitation of this remotely exploitable vulnerability, with Rockwell self-reported, may allow remote, authenticated users to bypass FactoryTalk Security policies based on a computer name.
Rockwell Automation reports this vulnerability affects the following versions of FactoryTalk Security:
- FactoryTalk Services Platform v6.11 and earlier, if FactoryTalk Security is enabled and deployed
In the vulnerability, FactoryTalk Services Platform contains an issue that may allow a remote, authenticated attacker to bypass FactoryTalk Security policies based on the computer name. If successfully exploited, this may allow an attacker to have the same privileges as if they were logged on to the client machine.
CVE-2021-32960 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.5.
The product sees use in the chemical, commercial facilities, critical manufacturing, energy, government facilities, and water and wastewater systems sectors. It also sees action on a global basis.
No known public exploits specifically target this vulnerability. This vulnerability has a high attack complexity.
Rockwell Automation encourages those using the affected software to update to FactoryTalk Services Platform v6.20 or later to address the associated risk.
Users who are unable to update are directed toward risk mitigation strategies provided below and are encouraged, when possible, to combine these tactics with the general security guidelines to employ multiple strategies simultaneously:
- When possible, do not utilize remote desktop connections.
- Use Microsoft Event Logger or similar event logging application to monitor atypical remote desktop connections and disconnections. Information on Setting up Windows Event Logs is available at Knowledgebase Article QA5965.
Rockwell recommends the following general security guidelines:
- Run all software as User, not as an Administrator, to minimize the impact of malicious code on the infected system.
- Ensure the least-privilege user principle is followed, and user/service account access to shared resources (such as a database) is only granted with a minimum number of rights as needed.
- When remote access is required, use secure methods, such as virtual private networks (VPNs), recognizing that VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices.
Click on the Rockwell Automation publication regarding this issue for more information.