Corrosion of metal grates does not happen overnight. As a matter of fact, it may happen over a periods of multiple decades and it becomes apparent no one really notices the areas we walk on; we just gloss over that in an effort to get to our appointed rounds.
In a separate incident at a different facility on May 4, an electrician fell through a grating area where they were conducting repair work, according to the BSEE report.
The electrician was surveying lighting repairs when he stepped on a section of grating that gave way beneath him. He was able to catch himself using his arms to prevent falling through to the plus-10 decking 40 feet below. Luckily, other employees in the area were able to assist him to safety.
As a result of these incidents, BSEE recommends operators and contractors consider the following:
- Review Safety Alert 353 with your workers, discuss hazardous areas and encourage feedback to ensure understanding
Inspect your facility to confirm the integrity of decks, grating, and structural and support beams - Ensure that any area of marginal or suspect strength is identified, clearly marked, and appropriately barricaded. Take measures to immediately repair, replace or mitigate the identified areas, and inform workers of these zones
- Ensure all personnel within areas of marginal or suspect strength follow all facility- level fall protection practices in job planning and conducting operations
Ensure Job Safety Analysis is conducted and reviewed prior to the start of operation