Siemens has updates available to handle an incorrect calculation vulnerability in its SCALANCE XM-400, XR-500, according to a report with CISA.
Successful exploitation of this remotely exploitable vulnerability, which Siemens self-reported, could allow an unauthenticated remote attacker to create a permanent denial-of-service condition.
The following Siemens products suffer from the issue:
- SCALANCE XM-400 Family: All versions prior to v6.4
- SCALANCE XR-500 Family: All versions prior to v6.4
An unauthenticated remote attacker could create a permanent denial-of-service condition by sending specially crafted OSPF packets. Successful exploitation requires OSPF to be enabled on an affected device.
CVE-2020-28393 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
The product sees use in multiple industry sectors, and on a global basis.
No known public exploits specifically target this vulnerability. However, an attacker with low skill level could leverage the low complexity vulnerability.
Siemens recommends applying updates where available:
- SCALANCE XM-400 Family: Update to v6.4 or laterÂ
- SCALANCE XR-500 Family: Update to v6.4 or laterÂ
Siemens identified the following specific workarounds and mitigations users can apply to reduce the risk:
- Disable OSPF in layer 3 configuration menu (note OSPF is disabled by default). This vulnerability is not exploitable, when OSPF is disabled.
- If OSPF is used, set a password for the OSPF interface and enable MD5 authentication.
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to the Siemens operational guidelines for Industrial Security and following the recommendations in the product manuals.