Siemens has an update available to handle an improper privilege management vulnerability in its Mendix, according to a report with CISA.

Successful exploitation of this remotely exploitable vulnerability, discovered by FlowFabric BV, could allow a non-administrative user to gain administrative privileges.

Siemens reports the vulnerability affects the following Mendix products:

  • Mendix Applications using Mendix 7: All versions prior to v7.23.19
  • Mendix Applications using Mendix 8: All versions prior to v8.17.0
  • Mendix Applications using Mendix 8 (v8.12): All versions prior to v8.12.5
  • Mendix Applications using Mendix 8 (v8.6): All versions prior to v8.6.9
  • Mendix Applications using Mendix 9: All versions prior to v9.0.5

In the vulnerability, authenticated, non-administrative users could modify their privileges by manipulating the user role under certain circumstances, allowing them to gain administrative privileges.

Schneider Bold

CVE-2021-27394 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.1.

The product sees use in multiple industrial sectors, and on a global basis.

No known public exploits specifically target this vulnerability. However, an attacker with low skill level could leverage this low complexity vulnerability.

Siemens released an update for Mendix and recommends updating to the latest version. In SSA-875726, Siemens lists the following remediations:

  • Mendix Applications using Mendix 7: Update Mendix Project to v7.23.19 or later version and redeploy the application. Mendix Applications using
  • Mendix 8: Update Mendix Project to v8.17.0 or later version and redeploy the application. 
  • Mendix Applications using Mendix 8 (v8.12): Update Mendix Project to v8.12.5 or later and preferably the latest V8.18 version and redeploy the application. 
  • Mendix Applications using Mendix 8 (v8.6): Update Mendix Project to v8.6.9 or later and preferably the latest V8.18 version and redeploy the application. Mendix Applications using Mendix 9: Update Mendix Project to v9.0.5 or later version and redeploy the application. 

Siemens recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ Operational Guidelines for Industrial Security, and following the recommendations in the product manuals.

Click here for additional information on Industrial Security by Siemens.