Siemens has an updated version to handle a use of client-side authentication vulnerability in its SIPORT MP, according to a report with CISA.

Successful exploitation of this remotely exploitable vulnerability, which Siemens self-reported, could allow an authenticated attacker to impersonate other users of the system and perform (potentially administrative) actions on behalf of those users if the single sign-on feature (“Allow logon without password”) is enabled.

The following versions of SIPORT MP, a system for access control and time management within the Siveillance Access Suite, suffer from the issue: Versions 3.2.1 and prior.

In the issue, the affected product has an authentication bypass, which could make it vulnerable to an attacker impersonating a system user.

CVE-2020-7591 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.8.

Schneider Bold

The product sees use mainly in the commercial facilities sector. It also sees action on a global basis.

No known public exploits specifically target this vulnerability. However, an attacker with low skill level could leverage the vulnerability.

Siemens released an updated version (v3.2.1) of SIPORT MP and recommends users install this update on all affected systems.

Siemens has identified the following specific workarounds and mitigations users can apply: For installations where the update to Version 3.2.1 is not possible, contact Siemens support for deployment and specific mitigation measures.

For additional information, please refer to Siemens Security Advisory SSA-384879.

As a general security measure, Siemens recommends users to protect network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices in order to run the devices in a protected IT environment.

Pin It on Pinterest

Share This