Siemens/PKE has an update available to handle multiple vulnerabilities in its Control Center Server (CCS), according to a report with CISA.

The remotely exploitable vulnerabilities include a cleartext storage of sensitive information in GUI, improper authentication, relative path traversal, use of a broken or risky cryptographic algorithm, exposed dangerous method or function, path traversal, cleartext storage in a file or on disk, SQL injection, cross-site scripting, and insufficient logging.

Successful exploitation of these vulnerabilities, discovered by Raphaël Rigo of Airbus Security Lab, may allow an attacker to read and write arbitrary files and sensitive data and execute commands and arbitrary code.

The following versions of CCS, a video management platform, suffer from the issues:

  • CCS: All versions prior to v1.5.0
  • CCS: v1.5.0 and later are affected by CVE-2019-18340

In one issue, the user configuration menu in the web interface of CCS transfers user passwords in clear to the client (browser).

Schneider Bold

CVE-2019-13947 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 4.9.

In addition, CCS contains an authentication bypass vulnerability in its XML-based communication protocol as provided by default on Ports 5444/TCP and 5440/TCP.

CVE-2019-18337 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.

Also, CCS contains a directory traversal vulnerability in its XML-based communication protocol as provided by default on Ports 5444/TCP and 5440/TCP.

CVE-2019-18338 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.7.

In another issue, CCS stores user and device passwords by applying weak cryptography.

CVE-2019-18340 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 5.5.

In addition, the SFTP service (default Port 22/TCP) of CCS contains an authentication bypass vulnerability.

CVE-2019-18341 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 5.3.

Also, the SFTP service (default Port 22/TCP) of CCS does not properly limit its capabilities to the specified purpose.

CVE-2019-18342 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.9.

In another issue, a specific section in the web interface of CCS contains a path traversal vulnerability that could allow an authenticated remote attacker to access and download arbitrary files from the server where CCS is installed.

CVE-2019-19290 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.5.

In addition, the FTP services of CCS maintain log files that store login credentials in cleartext. In configurations where the FTP service is enabled, authenticated remote attackers could extract login credentials of other users of the service.

CVE-2019-19291 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 5.3.

Also, CCS is vulnerable to an SQL injection in its XML-based communication protocol as provided by default on Ports 5444/TCP and 5440/TCP. An authenticated remote attacker could exploit this vulnerability to read or modify the CCS database and potentially execute administrative database operations or operating system commands.

CVE-2019-19292 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.8.

In another issue, the web interface of CCS contains a reflected cross-site scripting (XSS) vulnerability that could allow an unauthenticated remote attacker to steal sensitive data or execute administrative actions on behalf of a legitimate administrator of the CCS web interface.

CVE-2019-19293 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.1.

In addition, the web interface of CCS contains multiple stored XSS vulnerabilities in several input fields. This could allow an authenticated remote attacker to inject malicious JavaScript code into the CCS web application that is later executed in the browser context of any other user who views the relevant CCS web content.

CVE-2019-19294 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 6.3.

Also, CCS does not enforce logging of security-relevant activities in its XML-based communication protocol as provided by default on Ports 5444/TCP and 5440/TCP. An authenticated remote attacker could exploit this vulnerability to perform covert actions not visible in the application log.

CVE-2019-19295 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 4.3.

The product sees use mainly in the commercial facilities sector, and on a global basis.

No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage these low complexity vulnerabilities.

Siemens recommends users update to v1.5.0 or later.

Siemens identified the following workarounds and mitigations users can apply to reduce the risk:

  • General (applies to all vulnerabilities listed in this advisory) – Apply ACL/firewall configuration on the CCS server to ensure only legitimate systems can access the configured CCS server ports. Harden the CCS server accordingly to prevent unauthorized access. Consider applying encryption and authentication on the network (e.g., via TLS on application level or via IPSec on host level).
  • Harden the CCS server to prevent local access by unauthorized users.
  • Disable the web interface of CCS if not used. Alternatively, restrict access from localhost only, or only to trusted hosts of CCS administrators.
  • Enable TLS for the web interface of CCS.
  • Disable the FTP service of the CCS.

As a general security measure Siemens recommends protecting network access to affected products with appropriate mechanisms. It is advised to follow recommended security practices to run the devices in a protected IT environment.