Schneider Electric has a fix available to handle an improper restriction of XML external entity reference vulnerability in its SoMachine Basic, according to a report with CISA.

Successful exploitation of this remotely exploitable vulnerability, discovered by Gjoko Krstikj of Applied Risk, may result in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. Schneider Electric reports this vulnerability affects the following SoMachine Basic: All versions prior to v1.6 SP1.

In one issue, Schneider Electric SoMachine Basic prior to v1.6 SP1 suffers from an XML External Entity (XXE) vulnerability using the DTD parameter entities technique resulting in disclosure and retrieval of arbitrary data on the affected node via out-of-band (OOB) attack. This vulnerability is triggered when input passed to the xml parser is not sanitized while parsing the xml project/template file.

CVE-2018-7783 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.6.

The product sees use in the critical manufacturing; dams; defense industrial base; energy; food and agriculture; government facilities; nuclear reactors, materials, and waste; transportation systems, and water and wastewater systems. The product sees action on a global basis.

Schneider Bold

No known public exploits specifically target this vulnerability. However, an attacker with low skill level could leverage the issue.

To mitigate the issue, Schneider Electric replaced SoMachine Basic with EcoStruxure Machine Expert – Basic. The following steps are recommended for mitigation of this issue:

STEP 1: Update software and firmware:

STEP 2: Update projects in EcoStruxure Machine Expert – Basic:

  • Upgrade the functional level of the application to minimum Version 10.2
  • Activate the application protection for both read and write in the project properties.

STEP 3: Transfer applications:

  • Transfer applications to Modicon M100/M200/M221 logic controllers. EcoStruxure Machine Expert – Basic will perform an integrity check when transferring the application and will display a warning pop-up to the user if the application has been altered during transfer.

Click on Schneider’s publication SEVD-2018-142-01 for more information.

Schneider Electric also recommends the following general security practices:

  • Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network.
  • Install physical controls so no unauthorized personnel can access your industrial control and safety systems, components, peripheral equipment, and networks.
  • Place all controllers in locked cabinets and never leave them in the “Program” mode.
  • Never connect programming software to any network other than the network for the devices it is intended for.
  • Scan all methods of mobile data exchange with the isolated network such as CDs, USB drives, etc. before use in the terminals or any node connected to these networks.
  • Never allow mobile devices that have connected to any other network besides the intended network to connect to the safety or control networks without proper sanitation.
  • Minimize network exposure for all control system devices and systems and ensure they are not accessible from the Internet.
  • When remote access is required, use secure methods, such as virtual private networks (VPNs). Recognize VPNs may have vulnerabilities and should be updated to the most current version available. Also, understand VPNs are only as secure as the connected devices.

For more information click on the Schneider Electric Recommended Cybersecurity Best Practices document.