Successful exploitation of this remotely exploitable vulnerability, which Siemens self-reported, could allow a remote attacker to cause a denial-of-service condition.
The following products suffer from the issue: TIM 1531 IRC (incl. SIPLUS NET variants), all versions prior to v2.2.
In the vulnerability, during key agreement in a TLS handshake using a DH(E)-based cipher suite, a malicious server can send a very large prime value to the client. This will cause the client to spend an unreasonably long period of time generating a key for this prime, resulting in a hang until the client has finished. This could be exploited in a denial-of-service attack.
CVE-2018-0732 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.5.
The product sees use in multiple industrial sectors, and on a global basis.
No known public exploits specifically target this vulnerability. However, an attacker with low skill level could leverage the low complexity vulnerability.
Siemens recommends updating the following products to the latest version: TIM 1531 IRC (incl. SIPLUS NET variants): Update to v2.2 or later.Â
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to the Siemens operational guidelines for Industrial Security and following the recommendations in the product manuals.
For additional information, click on Siemens Security Advisory SSA-419820.