Siemens has an upgrade available to handle cross-site scripting, SQL injection, and improper access control vulnerabilities in its Opcenter Execution Core, according to a report with CISA.
Successful exploitation of these remotely exploitable vulnerabilities may allow an attacker to obtain session cookies, read and modify application data, read internal information, and perform unauthorized changes. Should the attacker gain access to the session cookies, they could then hijack the session and perform arbitrary actions in the name of the victim.
The following products suffer from the vulnreabilities:
- Camstar Enterprise Platform: All versions
- Opcenter Execution Core: All versions prior to v8.2
In one issue, an authenticated user with the ability to create containers, packages, or register defects could perform stored cross-site scripting (XSS) attacks within the vulnerable software.
CVE-2020-7576 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.5.
In addition, an authenticated user could perform an SQL injection attack by passing a modified SQL query through an input field to the back-end server.
CVE-2020-7577 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.1.
Also, authenticated users could have access to resources they normally would not have. This vulnerability could allow an attacker to view internal information and perform unauthorized changes.
CVE-2020-7578 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.1.
The product sees use mainly in the critical manufacturing sector, and on a global basis.
No known public exploits specifically target these vulnerabilities. However, an attacker with low skill level could leverage the issues.
Siemens recommends users upgrade to Opcenter Execution Core v8.2 (login required).
Siemens identified the following specific workarounds and mitigations that can reduce risk:
Configure a web application firewall to filter traffic containing XSS Injection and SQL Injections
Restrict access to application webserver for trusted users only
As a general security measure, Siemens recommends protecting network access to devices with appropriate mechanisms. To operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for Industrial Security and following the recommendations in the product manuals.
Click here for additional information on Industrial Security by Siemens.
For more information on these vulnerabilities and associated software updates, please see Siemens security advisory SSA-604937.