Texas Instruments has an upgrade available to handle stack-based buffer overflow and integer overflow or wraparound vulnerabilities in its SimpleLink Wi-Fi, MSP432, CC13XX, CC26XX, CC32XX, CC3100, according to a report with CISA.
Successful exploitation of these remotely exploitable vulnerabilities, discovered by David Atch and Omri Ben Bassat from Microsoft, could result in memory corruption, allowing remote code execution and causing a denial-of-service condition.
The following Texas Instruments products suffer from the vulnerabilities:
- SimpleLink MSP432E4 SDK: v4.20.00.12 and prior
- SimpleLink CC32XX SDK: v4.30.00.06 and prior
- SimpleLink CC13X0 SDK: versions prior to v4.10.03
- SimpleLink CC13X2 SDK: versions prior to v4.40.00
- SimpleLink CC26XX SDK: versions prior to v4.40.00
- CC3200 SDK: v1.5.0 and prior
- CC3100 SDK: v1.3.0 and prior
In one issue, an integer overflow exists in the APIs of the host MCU while trying to connect to a WIFI network may lead to issues such as a denial-of-service condition or code execution.
CVE-2021-22677 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 8.4.
In addition, the affected product is vulnerable to stack-based buffer overflow while processing over-the-air firmware updates from the CDN server, which may allow an attacker to remotely execute code.
CVE-2021-22673 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.2.
Also, the affected product is vulnerable to integer overflow while parsing malformed over-the-air firmware update files, which may allow an attacker to remotely execute code.
CVE-2021-22675 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 7.2.
In another issue, the affected product is vulnerable to an integer overflow while processing HTTP headers, which may allow an attacker to remotely execute code.
CVE-2021-22679 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
In addition, multiple integer overflow issues exist while processing long domain names, which may allow an attacker to remotely execute code.
CVE-2021-22671 is the case number assigned to this vulnerability, which has a CVSS v3 base score of 9.8.
The product sees use in multiple industrial sectors, and on a global basis.
No known public exploits specifically target these vulnerabilities. However, an attacker could leverage the low attack complexity vulnerabilities.
Texas Instruments recommends users upgrade to the latest software version.
Texas Instruments also recommends users only connect to trusted Wi-Fi networks.